iRADiX

Largest meeting place of Imaging Professionals

Tue05222012

Last update 05:15:00 AM IST

Back Computed Tomography Complete Systems Somatom Definition Flash dual-source CT
  • PDF
Computed Tomography Complete Systems Somatom Definition Flash dual-source CT
 
Somatom Definition Flash dual-source CT

General Features

Vendor
Siemens
Product Brief
Dual Multislice CT system
CT scanner mode
Dual
Year product introduced
2008

System Features

General
This new generation of dual- source CT scanners, featuring two X-ray tubes and two detectors, will provide a genuine innovation boost to dual-source technology. The enormous speed of the SOMATOM Definition Flash offers decisive advantages, especially regarding examinations of moving structures, such as the thorax and the heart. The gantry (i.e., the X-ray detector system surrounding the bore) rotates about its own axis in just 0.28 s. It is this extraordinary rotational speed that enables a scan speed never before attained in CT (i.e., up to 43 cm per second) and temporal resolution of 75 milliseconds.
Special Features
Split-second thorax
Scanning the thorax incl. the heart needs 0.6 s, taking the burden of breath-holding off the patient and allowing functional imaging for body regions up to 48 cm.

Sub-mSv heart
Temporal resolution of 75 ms and scan speed of up to 43 cm/s make heart-scanning without beta-blockers possible and for the first time breath-hold optional with dose levels below 1 mSv.

Single dose Dual Energy
With the Selective Photon Shield Dual Energy scans are now dose neutral. Together with dramatically increased energy separation and a wide range of FDA-cleared applications, it’s now perfect for routine clinical use.

Organ-sensitive dose protection
The SOMATOM Definition Flash prevents clinically irrelevant dose for spiral examinations and introduces for the first time organ-sensitive dose protection.

Technical details

Slices per rotation
2 x 128

More Info

Download Brochure
Download Brochure

Somatom Definition Flash dual-source CT Somatom Definition Flash dual-source CT Hot

User rating
 
4.3 (1)
The Somatom Definition Flash is a new dual-source CT from Siemens, featuring two X-ray tubes that simultaneously revolve around the patient's body. The fastest scanning speed in CT (i.e., 43 cm/s) and a temporal resolution of 75 ms, enable for example complete scans of the entire chest region in just 0.6 seconds. Thus, patients are no longer required to hold their breath during the exam the way they had in the past. At the same time, the Somatom Definition Flash operates at an extremely reduced radiation dose. For example, a spiral heart scan can be performed with less than 1 millisievert (mSv), whereas the average effective dose required for this purpose usually ranges from 8 mSv to 40 mSv. The new CT scanner will be available for sale in the first quarter of 2009.

Image Gallery

Somatom Definition Flash dual-source CT
Somatom Definition Flash dual-source CT
Somatom Definition Flash dual-source CT
Somatom Definition Flash dual-source CT

User reviews

Average user rating from: 1 user(s)

Overall rating 
 
4.3
Image resolution 
 
5.0  (1)
Image reconstruction 
 
5.0  (1)
Ease of handling 
 
4.0  (1)
Design 
 
4.0  (1)
Performance 
 
4.0  (1)
Value for Money 
 
4.0  (1)
Technical Support 
 
4.0  (1)
Ratings (the higher the better)
Image resolution*  
Quality of image resolution
Image reconstruction*  
Ease and output of Images of after reconstruction
Ease of handling*  
User friendliness
Design*  
Overall design and look
Performance*  
Overall performance in the long run (breakdown, technical difficulties faced)
Value for Money*  
Output in view of investment
Technical Support*  
Support from company in case of breakdown
Comments
    Please enter the security code.
 
 
Somatom Definition Flash dual-source CT 2009-02-17 15:05:41 Dr. Dinesh Chauhan
Overall rating 
 
4.3
Image resolution 
 
5.0
Image reconstruction 
 
5.0
Ease of handling 
 
4.0
Design 
 
4.0
Performance 
 
4.0
Value for Money 
 
4.0
Technical Support 
 
4.0
Dr. Dinesh Chauhan Reviewed by Dr. Dinesh Chauhan    February 17, 2009

--------------

i had opportunity to work on somatom definition.
this has wonderful technology ,good resolution and 3-d reconstruction, excellent for coronary artery studies

Was this review helpful to you? 
20
Report this review